UPS and EPS switchover times: what under 20 ms means
Switchover time is how long the station takes to move a load to battery when wall power drops. Printed figures run from 30 ms on the EcoFlow RIVER 2 to 10 ms on the DELTA 3. A 0 ms figure appears only in an online mode.
By the Power Station Chart team, checked against the documents listed at the end. How we review. Last reviewed October 31, 2026.
A figure and a disclaimer in one document
Jackery prints a 20 ms switchover for the Explorer 1000 v2. The same station carries the line "This product does not support 0ms switching." Both statements stand together. A 20 ms switchover is a short gap, and 0 ms means none at all. A switchover figure only means something alongside the word that comes with it.
What each maker prints
Makers use three labels, UPS, EPS and basic UPS, and attach them to different times.
Jackery's older Plus and Pro stations call the same function EPS and list 20 ms for it. EcoFlow's RIVER 3 manual separates two models. One has a 10 ms UPS. The other transfers within 20 ms and is labeled EPS. So one brand can sell the same station size with different labels, and the label tracks the switching time.
| Jackery Explorer 1000 v2 | UPS, 20 ms; no 0 ms switching |
|---|---|
| EcoFlow RIVER 2 | EPS or basic UPS, 30 ms, not 0 ms |
| EcoFlow DELTA 3 | UPS in standby, 10 ms |
| Jackery Explorer 5000 Plus | backup UPS under 20 ms; online UPS 0 ms |
| EcoFlow DELTA Pro Ultra | backup UPS under 20 ms; online UPS 0 ms in the US |
Standby and online modes
Larger stations print two modes and two times. The Explorer 5000 Plus lists a backup UPS under 20 ms and an online UPS at 0 ms. It says the online mode has to be switched on in its app. Bluetti prints a similar split on its AC300, with no delay for online UPS and 20 ms from standby.
The word online does not always bring 0 ms. The DELTA 3 prints a standby UPS at 10 ms. Its larger DELTA 3 Max prints an online mode at the same 10 ms. Count the number, not the mode name.
Across the four brands, the printed times cluster in a few steps. Of 74 stations that print a switchover time, 35 list 20 ms, 30 list 10 ms, 5 list 30 ms and 4 list 15 ms. Five EcoFlow models account for all of the 30 ms entries. They run from the RIVER 2 line to the DELTA 2 and the original DELTA Pro.
Wording also shifts between documents from one maker. Anker's C300 manual says under 10 ms, while its spec page says 10 ms. Jackery's pages describe some stations as under 20 ms and others as 20 ms. Treat 10 ms and under 10 ms as the same class of backup.
What the number does not say
EcoFlow's own article draws the line plainly. It calls EPS the emergency mode for loads that tolerate a brief interruption. It says a true UPS is often under 10 ms. It states that computers hold charge in capacitors for only a few milliseconds. It also says 20 ms is the figure generally acceptable, and that EPS timing sits at the edge of what most computers tolerate.
Those are the maker's statements about typical equipment. A station's spec cannot see what a particular device will accept. The device's own manual gives its ride-through time, and EcoFlow's checklist ends with a live test under a real load. A station that lists 10 ms is faster than one that lists 30 ms. Neither listing says anything about a specific load.
Products named above
- Jackery Explorer 1000 v21,070 WhCheck price on Amazon
- EcoFlow RIVER 2243 WhCheck price on Amazon
- EcoFlow DELTA 31,024 WhCheck price on Amazon
- Jackery Explorer 5000 Plus5,040 WhCheck price on Amazon
- EcoFlow DELTA Pro Ultra6,144 Wh
FAQ
What does under 20 ms mean?
It means the station moves the load to battery in less than 20 thousandths of a second. It is a ceiling, not the typical time, and it is slower than the 0 ms that online UPS modes print.
Is EPS the same as UPS?
Different makers use the two terms for the same function, and the times differ. Jackery's Explorer 1000 Plus calls its 20 ms function EPS. EcoFlow's RIVER 2 lists EPS as a basic UPS at 30 ms.
Do all stations have a switchover time?
No. A station without an AC outlet has nothing to switch, and 9 of the 81 stations leave the line blank. Several Anker and Bluetti models are among them.