How to read a panel datasheet

A panel datasheet gives six numbers that matter for a power station. Anker's PS200 prints Pmax 200 W, Voc 57.6 V, Vmp 48 V, Isc 4.38 A and Imp 4.16 A, all at standard test conditions. The sixth is the temperature coefficient.

By the Power Station Chart team, checked against the documents listed at the end. How we review. Last reviewed October 31, 2026.

Checks that catch a typo

Bluetti's SORA 500 manual prints 12.22 A for the panel's current at maximum power, while a product page prints 10.22 A. Multiplication settles it. The manual's 40.92 V times 12.22 A is 500 W, which matches the panel's name. A quick check like this is the fastest way to decide which of two printed values to trust.

Vmp multiplied by Imp should land near Pmax in every case. The Anker PS200 gives 48 V times 4.16 A, or about 200 W. The EcoFlow 400 W panel gives 31.0 V times 12.9 A, or about 400 W.

Voc should also run higher than Vmp, by about 20 percent on the PS200 (57.6 V against 48 V). If the numbers break these patterns, the sheet has a misprint or belongs to a different model.

The six numbers

Every figure in the electrical section is measured at standard test conditions. The International Association of Electrical Inspectors describes them as 1,000 watts per square meter of light with the cells at 25 °C. Real mornings and afternoons seldom match that.

PmaxRated peak power; 200 W on the PS200
VocOpen-circuit voltage, the highest the panel shows; 57.6 V on the PS200
VmpVoltage at maximum power; 48 V on the PS200
IscShort-circuit current, the highest current; 4.38 A on the PS200
ImpCurrent at maximum power; 4.16 A on the PS200
Temperature coefficientChange in voltage per °C; -0.26 percent on the SolarSaga 500 X

Read the tolerance before the number

EcoFlow's 400 W rigid panel prints a Voc of 37.1 V with a 3 percent tolerance. Its Isc of 13.79 A carries a 5 percent tolerance. A unit can read up to about 38.2 V and 14.5 A and still match the label. A margin that looks comfortable on paper can shrink by that much.

Anker's datasheet gives the PS200 a power tolerance of 5 percent and a maximum system voltage of 75 VDC. That 75 V is a limit of the panel, not of any station it connects to. A 5 percent tolerance on 200 W is a spread of 10 W either way. A label of 200 W can mean anything from 190 W to 210 W.

Tolerance also stacks with cold. The top of the EcoFlow tolerance is 38.2 V. The IAEI article uses a 1.18 factor for -17 °C. Together they reach about 45.1 V, against 43.8 V from the label value.

Which number goes where

A station's solar window compares against three of these numbers. Voc, after a cold-weather correction, goes against the maximum voltage. Vmp goes against the minimum, and Isc against the current cap. Pmax is only informational, because the station caps its own intake. The solar panel fit checker asks for those inputs. The correction itself is explained in why cold mornings raise panel voltage.

Two coefficients can appear on one datasheet. Jackery's SolarSaga 200 manual prints -0.27 percent per °C for voltage and -0.33 percent per °C for power. Only the first belongs in a voltage check. Anker's datasheet for the PS200 prints neither.

One more trap is a spec that describes a bundle. Jackery's manual for the SolarSaga 500 X says its figures are for six panels wired in parallel. Those numbers do not describe a single small panel.

Products named above

FAQ

Which datasheet number should I compare with the station's voltage limit?

Voc, adjusted for cold weather, because it is the highest voltage the panel reaches. The station's lower limit is compared with Vmp instead.

What are standard test conditions?

A cell temperature of 25 °C and 1,000 watts per square meter of light, per the IAEI article. A rooftop panel in winter sits in different conditions, which is why Voc rises in the cold.

What if my panel's datasheet has no temperature coefficient?

Anker's PS200 datasheet is one example. The fit checker then falls back on -0.3 percent per °C, a default written out in its <a href="/methodology/">method notes</a>.

Where these figures come from